MODELS:
DF30 – DF36 – DF48 – DF60 DF30-3 – DF36-3 – DF48-3 – DF60-3 DF30-4 – DF36-4 – DF48-4 – DF60-4
MODEL ATTRIBUTES:
DIAGNOSTIC MODE:
Problems Related To the Surface Heaters:
PROBLEM | POSSIBLE CAUSE | TEST / ACTION |
POOR IGNITION AT GRIDDLE | Cracked or damaged electrode | Replace electrode |
Electrode not positioned properly to Infrared burner, not close enough to tile surface | Reposition electrode properly to Infrared burner. Electrode should be clear of the screen and 1/8” above the tile | |
Partially plugged holes in the burner tile | Clear as necessary with wire paper clip. Replace burner if too many burner holes are clogged. | |
Incorrect orifice size | Check orifice stamp number. Replace if incorrect | |
Gas pressure | Check gas pressure with a manometer | |
Blockages in mixer tube or orifice | Clear or clean as necessary | |
Bent orifice bracket holder | Straighten bracket holder so gas jet is aimed straight down mixing tube or replace bracket holder |